{"id":37283,"date":"2015-09-04T05:08:02","date_gmt":"2015-09-04T05:08:02","guid":{"rendered":"http:\/\/acessopercon.com.br\/percon\/?p=37283"},"modified":"2015-09-04T05:08:02","modified_gmt":"2015-09-04T05:08:02","slug":"fluke-1551a-e-1552a","status":"publish","type":"post","link":"https:\/\/acessopercon.com.br\/percon\/fluke-1551a-e-1552a\/","title":{"rendered":"Term\u00f4metro de vidro digital Fluke 1551AEx e 1552AEx"},"content":{"rendered":"<h1 style=\"text-align: justify;\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignleft size-full wp-image-36646\" src=\"https:\/\/acessopercon.com.br\/2022\/wp-content\/uploads\/2015\/09\/Fluke1551A-e-1552A.jpg\" alt=\"Fluke 1551A e 1552A\" width=\"224\" height=\"228\" \/>Term\u00f4metro de vidro digital Fluke 1551A e 1552A<\/h1>\n<p style=\"text-align: justify;\">Term\u00f4metro de vidro digital !! Isto na realidade n\u00e3o existe mas os leg\u00edtimos substituto dos term\u00f4metros de merc\u00fario em vidro s\u00e3o os term\u00f4metros digitais Fluke 1551A e 1552A com precis\u00e3o de \u00b1 0,05 \u00b0 C em toda a faixa 1551A ( -50 a 160 C ) \/ 1552A ( -80 a 300C ) . Estes term\u00f4metros s\u00e3o os novos &#8221; padr\u00f5es de ouro &#8221; da calibra\u00e7\u00e3o de temperatura industrial. Podem trabalhar em ambientes potencialmente explosivos pois s\u00e3o intrinsecamente seguro , operam com pilhas com 300 horas de vida \u00fatil e incluem certifica\u00e7\u00e3o NVLAP que \u00e9 reconhecida pelo Inmetro.<\/p>\n<h2 style=\"text-align: justify;\">Term\u00f4metros de vidro digital Fluke 1551A e 1552A\u00a0<script src=\"https:\/\/server.iad.liveperson.net\/hcp\/html\/mTag.js?site=17387962\" type=\"text\/javascript\" charset=\"iso-8859-1\"><\/script><\/h2>\n<form id=\"aspnetForm\" action=\"RichProducts.aspx?pid=72061&amp;url=%2f%2ffluke%2fbrpt%2fcalibracao-de-processos%2fcalibradores-de-temperatura%2ffcal-155x-stik-thermometer.htm%3f&amp;AssetType=&amp;mode=\" method=\"post\" name=\"aspnetForm\">\n<table id=\"tblMasterParent\" width=\"990\" cellspacing=\"0\" cellpadding=\"0\" align=\"center\">\n<tbody>\n<tr>\n<td>\n<table id=\"tblMainContent\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td>\n<table border=\"0\" width=\"970\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\">\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td>\n<table border=\"0\" width=\"690\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\">\n<table border=\"0\" width=\"690\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr id=\"_ctl0_MainContentPlaceHolder_trPrdTabs\">\n<td>\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td>\n<div align=\"left\">\n<div id=\"_ctl0_MainContentPlaceHolder_ucTabProduts_radMultPageHome\">\n<div id=\"_ctl0_MainContentPlaceHolder_ucTabProduts_pvSpecs\">\n<div>\n<table id=\"Table1\" border=\"0\" width=\"650\" cellspacing=\"0\" cellpadding=\"0\" align=\"left\">\n<tbody>\n<tr valign=\"top\">\n<td valign=\"top\">\n<table border=\"1\" width=\"100%\" cellspacing=\"0\" cellpadding=\"5\">\n<tbody>\n<tr bgcolor=\"#e9eff3\">\n<td><strong>Specifications<\/strong><\/td>\n<td><strong>1551A Ex<\/strong><\/td>\n<td><strong>1552A Ex<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Temperature range<\/strong><\/td>\n<td>-50 \u00b0C to 160 \u00b0C<br \/>\n(-58 \u00b0F to 320 \u00b0F)<\/td>\n<td>-80 \u00b0C to 300 \u00b0C<br \/>\n( -112 \u00b0F to 572 \u00b0F)<\/td>\n<\/tr>\n<tr>\n<td><strong>Accuracy (1 year)<\/strong><\/td>\n<td colspan=\"2\">\u00b1 0.05 \u00b0C (\u00b1 0.09 \u00b0F)<\/td>\n<\/tr>\n<tr>\n<td><strong>Display units<\/strong><\/td>\n<td colspan=\"2\">\u00b0C, \u00b0F<\/td>\n<\/tr>\n<tr>\n<td><strong>Sensor type<\/strong><\/td>\n<td>100 \u03a9 thin-film RTD<\/td>\n<td>100 \u03a9 wire-wound PRT<\/td>\n<\/tr>\n<tr>\n<td><strong>Probe temperature coefficient<\/strong><\/td>\n<td colspan=\"2\">0.00385 \u03a9\/\u03a9\/\u00b0C nominal<\/td>\n<\/tr>\n<tr>\n<td><strong>Sensor length<\/strong><\/td>\n<td>\u2264 10 mm<\/td>\n<td>\u2264 30 mm<\/td>\n<\/tr>\n<tr>\n<td><strong>Sensor position (from sheath tip)<\/strong><\/td>\n<td colspan=\"2\">3 mm (0.1 in)<\/td>\n<\/tr>\n<tr>\n<td><strong>Minimum immersion depth<\/strong><\/td>\n<td>7 cm (2.8 in)<\/td>\n<td>12 cm (4.8 in)<\/td>\n<\/tr>\n<tr>\n<td><strong>Probe sheath material<\/strong><\/td>\n<td colspan=\"2\">Stainless steel<\/td>\n<\/tr>\n<tr>\n<td><strong>Response time<\/strong><\/td>\n<td colspan=\"2\">4.8 mm diameter probe (3\/16 in): 14 seconds<br \/>\n6.35 mm diameter probe (1\/4 in): 21 seconds<\/td>\n<\/tr>\n<tr>\n<td><strong>Probe hysteresis<\/strong><\/td>\n<td colspan=\"2\">\u00b1 0.01 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td><strong>Temperature resolution<\/strong><\/td>\n<td colspan=\"2\">Selectable: 0.1, 0.01, 0.001 (default 0.01)<\/td>\n<\/tr>\n<tr>\n<td><strong>Sample rate<\/strong><\/td>\n<td colspan=\"2\">Selectable: 0.5 seconds, 1 seconds, 2 seconds (default 1 seconds)<\/td>\n<\/tr>\n<tr>\n<td><strong>Operating temperature range readout<\/strong><\/td>\n<td colspan=\"2\">-10 \u00b0C to 50 \u00b0C (14 \u00b0F to 122 \u00b0F)<\/td>\n<\/tr>\n<tr>\n<td><strong>Temperature resolution<\/strong><\/td>\n<td colspan=\"2\">Selectable: 0.1, 0.01, 0.001 (default 0.01)<\/td>\n<\/tr>\n<tr>\n<td><strong>Sample rate<\/strong><\/td>\n<td colspan=\"2\">Selectable: 0.5 seconds, 1 seconds, 2 seconds (default 1 seconds)<\/td>\n<\/tr>\n<tr>\n<td><strong>Operating temperature range readout<\/strong><\/td>\n<td colspan=\"2\">-10 \u00b0C to 50 \u00b0C (14 \u00b0F to 122 \u00b0F)<\/td>\n<\/tr>\n<tr>\n<td><strong>Storage temperature<\/strong><\/td>\n<td colspan=\"2\">-20 \u00b0C to 60 \u00b0C (-4 \u00b0F to 140 \u00b0F) 0 % to 95 % RH, non-condensing<\/td>\n<\/tr>\n<tr>\n<td><strong>Optional data logging<sup>1<\/sup><\/strong><\/td>\n<td colspan=\"2\">Up to 10,000 time-stamped readings stored to internal memory<\/td>\n<\/tr>\n<tr>\n<td><strong>Logging intervals<sup>1<\/sup><\/strong><\/td>\n<td colspan=\"2\">2 seconds, 5 seconds, 10 seconds, 30 seconds, or 60 seconds;<br \/>\n2 minutes, 5 minutes, 10 minutes, 30 minutes, or 60 minutes<\/td>\n<\/tr>\n<tr>\n<td><strong>Damping<\/strong><\/td>\n<td colspan=\"2\">Moving average of the most recent 2 to 10 readings<br \/>\n(ON\/OFF, 2, 5, 10)<\/td>\n<\/tr>\n<tr>\n<td><strong>Communications<\/strong><\/td>\n<td colspan=\"2\">RS-232 stereo jack (access calibration parameters only)<\/td>\n<\/tr>\n<tr>\n<td><strong>AC power<\/strong><\/td>\n<td colspan=\"2\">None<\/td>\n<\/tr>\n<tr>\n<td><strong>DC power<\/strong><\/td>\n<td colspan=\"2\">3-AAA Batteries, typical battery life of 300 hours without LCD backlight<\/td>\n<\/tr>\n<tr>\n<td><strong>EMC compliance<\/strong><\/td>\n<td colspan=\"2\">EN61326:2006 Annex C; CISPR II Edition 5.0-2009; Class \u201cB<\/td>\n<\/tr>\n<tr>\n<td><strong>Enclosure rating<\/strong><\/td>\n<td colspan=\"2\">IP50<\/td>\n<\/tr>\n<tr>\n<td><strong>Electronics dimensions (H x W x D)<\/strong><\/td>\n<td colspan=\"2\">114 mm x 57 mm x 25 mm<br \/>\n(4.5 in x 2.25 in x 1.0 in)<\/td>\n<\/tr>\n<tr>\n<td><strong>Weight<\/strong><\/td>\n<td colspan=\"2\">196 g (6.9 oz)<\/td>\n<\/tr>\n<tr>\n<td><strong>Calibration (included)<\/strong><\/td>\n<td colspan=\"2\">NVLAP-accredited, NIST-traceable<\/td>\n<\/tr>\n<tr>\n<td><strong>Characterization<\/strong><\/td>\n<td>CVD<\/td>\n<td>ITS-90<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/form>\n<p style=\"text-align: justify;\">\n<p style=\"text-align: justify;\"><strong><a class=\"dt-btn dt-btn-m dt-btn-submit ripple\" style=\"-webkit-tap-highlight-color: rgba(0, 0, 0, 0);\" title=\"Loja Virtual Percon\" href=\"https:\/\/acessopercon.com.br\/percon\/fale-conosco\/\" target=\"_blank\" rel=\"noopener\">Clique aqui para comprar este produto<\/a><\/strong><\/p>\n<h2 style=\"text-align: justify;\">Term\u00f4metro de vidro digital Fluke 1551A e 1552A<\/h2>\n<p style=\"text-align: justify;\">Term\u00f4metro de vidro digital 1551A e 1552A \u00a0e outros produtos da Fluke podem ser encontrados na PerCon Tecnologia que atua como canal de distribui\u00e7\u00e3o da Fluke e \u00e9 sediada na Rua Dias da Cruz 188 \u2013 Sub solo \u2013 M\u00e9ier (<a href=\"mailto:percon@acessopercon.com.br\">percon@acessopercon.com.br<\/a>) \/ Fone : 21-2596-8369<\/p>\n<p style=\"text-align: justify;\"><a class=\"dt-single-image\" href=\"https:\/\/acessopercon.com.br\/2022\/wp-content\/uploads\/2017\/08\/Fluke-e-na-PerCon.jpg\" rel=\"attachment wp-att-46042\" data-dt-img-description=\"\"><img decoding=\"async\" class=\"alignnone size-medium wp-image-46042\" src=\"https:\/\/acessopercon.com.br\/percon\/wp-content\/uploads\/2017\/08\/Fluke-\u00e9-na-PerCon-300x200.jpg\" alt=\"Fluke \u00e9 na PerCon\" width=\"300\" height=\"200\" \/><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Term\u00f4metro de vidro digital Fluke 1551A e 1552A Term\u00f4metro de vidro digital !! Isto na realidade n\u00e3o existe mas os leg\u00edtimos substituto dos term\u00f4metros de merc\u00fario em vidro s\u00e3o os term\u00f4metros digitais Fluke 1551A e 1552A com precis\u00e3o de \u00b1 0,05 \u00b0 C em toda a faixa 1551A ( -50 a 160 C ) \/ [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[114,218],"tags":[240],"_links":{"self":[{"href":"https:\/\/acessopercon.com.br\/percon\/wp-json\/wp\/v2\/posts\/37283"}],"collection":[{"href":"https:\/\/acessopercon.com.br\/percon\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/acessopercon.com.br\/percon\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/acessopercon.com.br\/percon\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/acessopercon.com.br\/percon\/wp-json\/wp\/v2\/comments?post=37283"}],"version-history":[{"count":0,"href":"https:\/\/acessopercon.com.br\/percon\/wp-json\/wp\/v2\/posts\/37283\/revisions"}],"wp:attachment":[{"href":"https:\/\/acessopercon.com.br\/percon\/wp-json\/wp\/v2\/media?parent=37283"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/acessopercon.com.br\/percon\/wp-json\/wp\/v2\/categories?post=37283"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/acessopercon.com.br\/percon\/wp-json\/wp\/v2\/tags?post=37283"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}