{"id":36207,"date":"2015-08-24T02:44:06","date_gmt":"2015-08-24T02:44:06","guid":{"rendered":"http:\/\/acessopercon.com.br\/percon\/?p=36207"},"modified":"2022-06-08T18:35:29","modified_gmt":"2022-06-08T18:35:29","slug":"nr33-teste-de-verificacao-e-calibracao","status":"publish","type":"post","link":"https:\/\/acessopercon.com.br\/percon\/nr33-teste-de-verificacao-e-calibracao\/","title":{"rendered":"NR33 teste de verifica\u00e7\u00e3o e calibra\u00e7\u00e3o de detectores gases"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"36207\" class=\"elementor elementor-36207\">\n\t\t\t\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-413c3be1 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"413c3be1\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-61316ed0\" data-id=\"61316ed0\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t\t\t<div class=\"elementor-element elementor-element-2c53496 elementor-widget elementor-widget-heading\" data-id=\"2c53496\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">NR33 bUMP TEST DE DETECTORES DE GASES<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-62555540 elementor-widget elementor-widget-text-editor\" data-id=\"62555540\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p><span style=\"color: var( --e-global-color-text ); font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-size: var( --e-global-typography-text-font-size ); font-weight: var( --e-global-typography-text-font-weight ); letter-spacing: var( --e-global-typography-text-letter-spacing ); word-spacing: var( --e-global-typography-text-word-spacing );\">Antes de iniciar um Teste de Resposta certifique-se que tenha as ferramentas necess\u00e1rias:<\/span><\/p><ul><li>Cilindro de gases com tipo e concentra\u00e7\u00e3o do g\u00e1s de teste \u2013 Padr\u00e3o BW 04 gases CO &#8211; 100 ppm H2S \u2013 25 ppm %LEL \u2013 50 % vol O2 \u2013 18 % vol Regulador de vaz\u00e3o Adaptador de calibra\u00e7\u00e3o Mangueira<\/li><li>Um teste de resposta confirma a capacidade do detector de g\u00e1s responder aos gases alvo. O teste de resposta exp\u00f5e o detector a concentra\u00e7\u00f5es de g\u00e1s que excedem as defini\u00e7\u00f5es de alarme confirmando a capacidade do sensor de responder ao g\u00e1s, portanto consiste em aplicar o g\u00e1s de refer\u00eancia (span) no equipamento, apenas para verifica\u00e7\u00e3o da resposta do detector ao contato com os gases, avaliando opera\u00e7\u00e3o dos alarmes, e se a leitura indicada no display atinge os spans de refer\u00eancia.<\/li><li>Conecte o g\u00e1s de teste, o regulador, a mangueira de amostragem e o adaptador de calibra\u00e7\u00e3o. Abra totalmente a v\u00e1lvula do regulador e conecte o adaptador de calibra\u00e7\u00e3o ao detector. A resposta ao g\u00e1s de teste dever\u00e1 ser quase imediata. Se os sensores n\u00e3o responderem, demorarem mais de um minuto para responder ou se as leituras n\u00e3o corresponderem \u00e1s concentra\u00e7\u00f5es do g\u00e1s de teste, calibre o detector e fa\u00e7a um novo teste de resposta.<\/li><\/ul><pre><strong>Procedimentos do Bump Test NR33 :<\/strong><\/pre><ul><li>Certifique-se de que a \u00e1rea esteja livre de gases perigosos e zere automaticamente o detector antes do teste. Use apenas gases de testes de qualidade superior ( Cilindros de calibra\u00e7\u00e3o ) .<\/li><\/ul><p>\u00a0<\/p><p><strong>Calibra\u00e7\u00e3o NR33<\/strong><\/p><p><em>Passo a passo da calibra\u00e7\u00e3o dos modelos: GasAlertMicroCLip XT, XL e X3.<\/em><\/p><p>A precis\u00e3o do seu detector de g\u00e1s \u00e9 ajustada atrav\u00e9s da calibra\u00e7\u00e3o. Uma forma f\u00e1cil de entender a calibra\u00e7\u00e3o \u00e9 dividila em um procedimento de duas etapas. Na primeira etapa, uma leitura de base (zero) \u00e9 efetuada em um ambiente de ar limpo. Na segunda etapa, os sensores s\u00e3o expostos a concentra\u00e7\u00f5es de gases conhecidas. O instrumento usa esta base e a concentra\u00e7\u00e3o de g\u00e1s conhecida para determinar a escala de medi\u00e7\u00e3o da sua resposta ao g\u00e1s. Importante: Calibre apenas em \u00e1reas seguras e livres de gases perigosos. N\u00e3o calibre o detector durante ou imediatamente ap\u00f3s a carga.<\/p><ul><li>Iniciar a calibra\u00e7\u00e3o Inicie o modo de calibra\u00e7\u00e3o mantendo pressionado o bot\u00e3o de comando para desativar o detector. Continue a manter o bot\u00e3o pressionado quando a unidade ler \u201cDESLIGA\u201d e ap\u00f3s o instrumento ter conclu\u00eddo o desligamento. O display LCD fica em branco por um breve per\u00edodo, depois o detector inicia a contagem regressiva da calibra\u00e7\u00e3o.<\/li><li>N\u00e3o solte o bot\u00e3o de comando at\u00e9 a contagem regressiva ser totalmente conclu\u00edda e o detector come\u00e7ar o procedimento de auto zero.<\/li><li>Durante o auto zero, o detector define sua base em um ambiente de ar limpo e fresco, onde as leituras esperadas s\u00e3o iguais a 20,9% para oxig\u00eanio, 0% LEL para gases combust\u00edveis e 0 ppm para gases t\u00f3xicos. Como uma precau\u00e7\u00e3o de seguran\u00e7a, o detector avisa sobre uma mensagem de erro se a defini\u00e7\u00e3o zero (base) Parecer estar fora do n\u00edvel esperado de par\u00e2metros predeterminados. Ap\u00f3s zerar os sensores, voc\u00ea ser\u00e1 aconselhado a aplicar o g\u00e1s de calibra\u00e7\u00e3o.<\/li><\/ul><pre><strong>Aplicar o g\u00e1s com cilindro de refer\u00eancia (NR 33)<\/strong><\/pre><p>Certifique-se de que tenha o tipo e as concentra\u00e7\u00f5es adequadas de gases, tubos de amostragem, reguladores e adaptador de calibra\u00e7\u00e3o. Ter as ferramentas corretas \u00e9 fundamental para uma calibra\u00e7\u00e3o precisa. Verifique todas as conex\u00f5es entre o g\u00e1s de calibra\u00e7\u00e3o, o regulador, a mangueira de amostragem e os encaixes de conex\u00e3o r\u00e1pida. Quando solicitar a aplicar g\u00e1s, abra totalmente a v\u00e1lvula do regulador e conecte o adaptador de calibra\u00e7\u00e3o ao detector.<\/p><p>Verifique todas as conex\u00f5es entre o g\u00e1s de calibra\u00e7\u00e3o, o regulador, a mangueira de amostragem e os encaixes de conex\u00e3o r\u00e1pida. Quando solicitar a aplicar g\u00e1s, abra totalmente a v\u00e1lvula do regulador e conecte o adaptador de calibra\u00e7\u00e3o ao detector.<\/p><p>Obs: Use apenas gases de calibra\u00e7\u00e3o de alta qualidade e rastre\u00e1veis.<\/p><pre><strong>Span autom\u00e1tico (NR33)<\/strong><\/pre><p>O diagn\u00f3stico de Span autom\u00e1tico do detector verifica se os n\u00edveis do g\u00e1s de calibra\u00e7\u00e3o detectados correspondem aos n\u00edveis previstos. Se 50% do valor esperado for atingido em 30 segundos, o detector emitir\u00e1 um bipe e continuar\u00e1 o span. Um Auto Span completo dura aproximadamente dois minutos. Depois de conclu\u00eddo, o detector avisa quando vence a pr\u00f3xima calibra\u00e7\u00e3o.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a952b3d elementor-widget elementor-widget-heading\" data-id=\"a952b3d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">cALIBRA\u00c7\u00c3O, TESTE DE RESPOSTA <br>E DEFINI\u00c7\u00d5ES DA NR33<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a919f7b elementor-widget elementor-widget-text-editor\" data-id=\"a919f7b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p><strong style=\"font-size: 30px; word-spacing: var( --e-global-typography-text-word-spacing );\">Calibra\u00e7\u00e3o NR33 <\/strong><\/p><div>De acordo com o a Portaria n\u00b0 232 de 08\/05\/12 &#8211; Vocabul\u00e1rio Internacional de Metrologia (VIM), \u201ccalibra\u00e7\u00e3o \u00e9 o conjunto de opera\u00e7\u00f5es que estabelece, sob condi\u00e7\u00f5es especificadas, a rela\u00e7\u00e3o entre os valores indicados por um instrumento de medi\u00e7\u00e3o e os valores correspondentes das grandezas estabelecidas por padr\u00f5es\u201d. Desta forma calibra\u00e7\u00e3o \u00e9 a rela\u00e7\u00e3o entre o valor indicado pelo detector e o valor do padr\u00e3o de g\u00e1s. Atrav\u00e9s desta opera\u00e7\u00e3o, pode-se estabelecer o \u201cerro de medi\u00e7\u00e3o\u201d do detector de g\u00e1s. No VIM, \u201cerro de medi\u00e7\u00e3o \u00e9 definido como sendo a \u201cDiferen\u00e7a entre o valor medido duma grandeza e o valor de refer\u00eancia\u201d. Se houver internamente um crit\u00e9rio ou limite de erro permiss\u00edvel para erro de medi\u00e7\u00e3o apresentado e, caso o erro for superior ao limite, se faz necess\u00e1rio um ajuste no instrumento, ou seja, o \u201cconjunto de opera\u00e7\u00f5es efetuadas num sistema de medi\u00e7\u00e3o, de modo que ele forne\u00e7a indica\u00e7\u00f5es prescritas correspondentes a determinados valores duma grandeza a ser medida\u201d.<\/div><div>\u00a0<\/div><p><strong>Teste de resposta ou Bump Test (NR33)\u00a0<\/strong><\/p><div>S\u00e3o termos que o mercado instituiu, baseados na defini\u00e7\u00e3o de \u201cverifica\u00e7\u00e3o de um instrumento de medi\u00e7\u00e3o\u201d da Portaria INMETRO n\u00b0 163 de 06\/09\/2005 (Vocabul\u00e1rio Internacional de Termos de metrologia Legal), conforme definido no item 3.12: \u201cProcedimento que compreende o exame, a marca\u00e7\u00e3o e\/ou a emiss\u00e3o de um certificado de verifica\u00e7\u00e3o e que constata e confirma que o instrumento de medi\u00e7\u00e3o satisfaz \u00e0s exig\u00eancias regulamentares\u201d. Interessante observar que o teste que o profissional realiza antes do uso do equipamento para verificar a condi\u00e7\u00e3o de funcionamento do detector de gases, confirmando a capacidade do instrumento em responder aos gases-alvo \u00e9 conhecido como Teste de resposta\/Bump Test e, em alguns casos, ambos os termos s\u00e3o utilizados no mercado como sin\u00f4nimo de calibra\u00e7\u00e3o<\/div><div>.<\/div><p><strong>Frequ\u00eancia de envio de detectores de gases para calibra\u00e7\u00e3o NR33\u00a0<\/strong><\/p><p>Este tema \u00e9 pol\u00eamico, muitos profissionais tem d\u00favidas a respeito da periodicidade exigida para realiza\u00e7\u00e3o da calibra\u00e7\u00e3o em laborat\u00f3rio, e as d\u00favidas surgem justamente pela norma regulamentadora, NR-33, n\u00e3o definir um prazo de retorno ao laborat\u00f3rio para nova calibra\u00e7\u00e3o. No entanto, o Vocabul\u00e1rio Internacional de Termos de metrologia legal define no item 3.16 a Verifica\u00e7\u00e3o Peri\u00f3dica como \u201cverifica\u00e7\u00e3o subseq\u00fcente de um instrumento de medi\u00e7\u00e3o efetuada periodicamente em intervalos de tempo especificados e segundo procedimentos fixados por regulamentos\u201d. Portanto, a responsabilidade por assegurar que o equipamento esteja em condi\u00e7\u00f5es de utiliza\u00e7\u00e3o (funcionamento de todos os recursos) \u00e9 da empresa, segundo seus procedimentos internos ou recomenda\u00e7\u00f5es do fabricante presentes no manual de instru\u00e7\u00f5es. Nesse respeito, entende-se que a responsabilidade pela defini\u00e7\u00e3o do intervalo de calibra\u00e7\u00e3o, aprova\u00e7\u00e3o dos resultados expressos no certificado de calibra\u00e7\u00e3o e aprova\u00e7\u00e3o do equipamento para uso \u00e9 da gest\u00e3o da seguran\u00e7a da empresa, que atrav\u00e9s de seus procedimentos e pol\u00edtica de seguran\u00e7a determina o intervalo de verifica\u00e7\u00e3o e\/ou calibra\u00e7\u00e3o na an\u00e1lise da atividade, nos riscos envolvidos e no hist\u00f3rico das condi\u00e7\u00f5es de trabalho.<\/p><p><strong>Quando realizar a Calibra\u00e7\u00e3o (Teste de Resposta ou Bump Test) NR33 ?\u00a0<\/strong><\/p><p>Se a periodicidade da calibra\u00e7\u00e3o em laborat\u00f3rio n\u00e3o est\u00e1 determinada na Portaria MTE n\u00b0 202 de 22\/12\/06 (NR-33), o teste de resposta ou bump testest\u00e1:<\/p><p><strong>Medidas t\u00e9cnicas de preven\u00e7\u00e3o NR33\u00a0<\/strong><\/p><p><em>Testar os equipamentos de medi\u00e7\u00e3o antes de cada utiliza\u00e7\u00e3o \u00e9<\/em>\u00a0tamb\u00e9m mencionado na<strong> NBR 14787:<\/strong><\/p><p>\u00a0<\/p><p>\u00a0<\/p><p><strong>Clique para assuntos relacionados <\/strong><\/p><p><strong><a href=\"https:\/\/acessopercon.com.br\/percon\/monitor-de-area-radius-bz1\/\">Monitor de \u00e1rea Radius BZ1<\/a><\/strong><\/p><p><a href=\"https:\/\/acessopercon.com.br\/percon\/detector-portatil-de-quatro-ou-cinco-gases\/\"><strong>Detector port\u00e1til de quatro ou cinco gases Ventis\u2122 Pro Series<\/strong><\/a><\/p><p><a href=\"https:\/\/acessopercon.com.br\/percon\/bump-test-ou-teste-de-verificacao\/\"><strong>Teste de verifica\u00e7\u00e3o ou bump test<\/strong><\/a><\/p><p><a href=\"https:\/\/acessopercon.com.br\/percon\/detectores-de-gases-nocoes-basicas\/\"><strong>No\u00e7\u00f5es b\u00e1sicas sobre detectores de gases<\/strong><\/a><\/p><p><a href=\"https:\/\/acessopercon.com.br\/percon\/deteccao-de-gases-e-os-tipos-de-sensores\/\"><strong>Tipos de sensores de detectores de gases<\/strong><\/a><\/p><p><a href=\"https:\/\/acessopercon.com.br\/percon\/calibracao-de-detectores-de-gases\/\"><strong>Calibra\u00e7\u00e3o de detectores de gases<\/strong><\/a><\/p><p><a href=\"https:\/\/acessopercon.com.br\/percon\/indsci-industrial-scientific\/\"><strong>Industrial Scientific<\/strong><\/a><\/p><p><a href=\"https:\/\/acessopercon.com.br\/percon\/aluguel-de-detectores-de-gases-e-instrumentos-de-teste\/\"><strong>Aluguel de detectores de gases<\/strong><\/a><\/p><p>\u00a0<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>NR33 bUMP TEST DE DETECTORES DE GASES Antes de iniciar um Teste de Resposta certifique-se que tenha as ferramentas necess\u00e1rias: Cilindro de gases com tipo e concentra\u00e7\u00e3o do g\u00e1s de teste \u2013 Padr\u00e3o BW 04 gases CO &#8211; 100 ppm H2S \u2013 25 ppm %LEL \u2013 50 % vol O2 \u2013 18 % vol Regulador [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[36,38],"tags":[40],"_links":{"self":[{"href":"https:\/\/acessopercon.com.br\/percon\/wp-json\/wp\/v2\/posts\/36207"}],"collection":[{"href":"https:\/\/acessopercon.com.br\/percon\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/acessopercon.com.br\/percon\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/acessopercon.com.br\/percon\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/acessopercon.com.br\/percon\/wp-json\/wp\/v2\/comments?post=36207"}],"version-history":[{"count":6,"href":"https:\/\/acessopercon.com.br\/percon\/wp-json\/wp\/v2\/posts\/36207\/revisions"}],"predecessor-version":[{"id":54525,"href":"https:\/\/acessopercon.com.br\/percon\/wp-json\/wp\/v2\/posts\/36207\/revisions\/54525"}],"wp:attachment":[{"href":"https:\/\/acessopercon.com.br\/percon\/wp-json\/wp\/v2\/media?parent=36207"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/acessopercon.com.br\/percon\/wp-json\/wp\/v2\/categories?post=36207"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/acessopercon.com.br\/percon\/wp-json\/wp\/v2\/tags?post=36207"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}